Reply To: Negative turbidity readings

Home Forums Mayfly Data Logger Negative turbidity readings Reply To: Negative turbidity readings

#19779
Shannon Hicks
Moderator

    Those old Campbell OBS3+ turbidity sensors will either flatline or go negative when they fail.  We started deploying dozens of that sensor model about 8 or 9 years ago and almost all of them have been removed from the field in the past few years due to failure.  It looks like your station is 8 years old so you got more life out of it than most.  To double-check that the sensor really is bad, you can put the Mayfly logger into continuous testing mode by pressing the D21 button, so that the sensors stay powered continuously for a few minutes.  Use a voltmeter to check the 5v output supply voltage of the Mayfly board, using the Vcc and Gnd pins of the screw terminal board that the turbidity sensor is connected to.  You should see around 5v when the sensor is being powered.  If not, your Mayfly board isn’t generating the 5v signal to power the sensor, or the sensor is drawing too much power (usually due to flooding of the sensor housing) so it is shorting out and causing a voltage sag on the supply.  You can also check the signal output voltage of the sensor by looking at the two sensor signal wires on the screw terminal board (test them individually, so measure across S1 and Gnd, then S2 and Gnd.)  Because I built and installed that particular station you’re referring to, I still have the voltage-to-NTU conversion calibration sheet from the manufacturer so I can send you the equations the logger uses to convert the raw analog voltage readings to NTU.  If you manually calculate the turbidity different than what the Mayfly is calculating, then it could possibly be the analog-to-digital converted on your logger board has gone bad, but this is rare.  It’s more likely that the sensor has simply died, but since Campbell doesn’t repair these anymore, you only option would be to replace it with something like the newer ClariVue turbidity sensor.