nick replied to the topic Continous HAB monitoring in the forum Mayfly Data Logger 1 year, 1 month ago
<p style=”text-align: left;”>I’m just connecting one Turner phyco c-flour sensor.</p>
I assume these resistor pairs are independent and shouldn’t affect how a single sensor reports.
<p style=”text-align: left;”>Thank you for the previous response regarding the cable glands.</p> -
Shannon Hicks replied to the topic Continous HAB monitoring in the forum Mayfly Data Logger 1 year, 1 month ago
Are you trying to measure 2 analog signals from 2 separate sensors with just one 6-pin screw terminal board?
-
nick replied to the topic Continous HAB monitoring in the forum Mayfly Data Logger 1 year, 1 month ago
Shannon, I went ahead and soldered four 10k resistors instead of the two I originally said, similar to what you did here:

Does that still work for my purposes or does it change things?
Thank you.
-
Shannon Hicks replied to the topic Logger not transmitting data to website in the forum Mayfly Data Logger 1 year, 1 month ago
That happens occasionally when the connection between the Mayfly and the online time server gets terminated before the entire timestamp gets transmitted, resulting in an incomplete timestamp, and the Mayfly code has some smarts to check whether the timestamp it received is a valid, reasonable date. If you ever get this error, you can just…[Read more]
-
Jamie Anderson started the topic Logger not transmitting data to website in the forum Mayfly Data Logger 1 year, 1 month ago
I have a new logger that is recording data to an SD card but I get the below error and the logger will not transmit to the website.
“Current clock timestamp not valid”
I used this sketch: https://github.com/EnviroDIY/ModularSensors/blob/master/examples/DRWI_SIM7080LTE/DRWI_SIM7080LTE.ino
-
neilh20 replied to the topic Hydros 21 Depth/Conductivity During low temps in the forum Environmental Sensors 1 year, 1 month ago
Hi Jake, no “pressure sensor” is going to be able to be linear/accurate if ice is forming and expanding in the protective enclosure round the pressure sensor. My guess is the whole sensor would have to be specially designed to allow for the ice expansion to even survive a freezing event.
My hypothesis (guess) would be that its the nearly…[Read more]
-
Jake Lemon replied to the topic Hydros 21 Depth/Conductivity During low temps in the forum Environmental Sensors 1 year, 2 months ago
Thanks for your thoughts Neil.
These blips are occurring over the course of hours (roughly 4-6 hours from when depth starts dropping until it reaches it’s lowest point) though the time varies by occurrence.
They seem to be happening as temperature approaches the freezing point. I’ve attached a graph with temp for reference.
-
AdrienneBP became a registered member 1 year, 2 months ago
-
neilh20 replied to the topic Hydros 21 Depth/Conductivity During low temps in the forum Environmental Sensors 1 year, 2 months ago
I wonder what the water temperature is, or if there are water temperature changes, when this is happening.
From the graph it reads the water level is at 20″ depth then on the 10th Feb it drops by up to 5″ for some time (hours?) before recovering, with 3 other similar but not us pronounced events
IF any for of ice could build up in a pressure…[Read more]
-
Jake Lemon started the topic Hydros 21 Depth/Conductivity During low temps in the forum Environmental Sensors 1 year, 2 months ago
Hi All. We’ve been seeing some strange depth and conductivity trends at a few of our sites. Quick drops in depth over a short period of time with a quick bounceback. See attached screenshot example. This occurred on the same days at multiple sites on different streams, but in the same region. At one site, conductivity dropped a bit at the same…[Read more]
-
kristenkieta became a registered member 1 year, 2 months ago
-
Kurt@UR replied to the topic Inexpensive DO probe recommendations in the forum Environmental Sensors 1 year, 2 months ago
The cathode is exposed. I did rinse the cathode when I cleaned everything and there was nothing obviously fouling it. The probe tip being under the membrane cap I considered pretty well protected. After examining my data and pictures of the probe tip, Atlas Scientific had no explanation other than saying maybe there was an unknown material…[Read more]
-
BrianJastram replied to the topic Inexpensive DO probe recommendations in the forum Environmental Sensors 1 year, 2 months ago
Hi Kurt,
In regard to downward trending DO readings, contamination, membrane damage, and electrolyte, is there an anode and cathode on your probe that you can clean? I used to use a YSI galvanic DO meter that would accumulate tarnish, which I would occasionally sand off to improve the responsiveness of the readings.
-
Scott Ensign replied to the topic Not able to download readings in the forum Monitor My Watershed 1 year, 2 months ago
Neil, there is a faster and more flexible way to extract data from Monitor My Watershed. Instead of using the CSV download button, try using either python or R to extract specific time periods of data for specific sensors and stations. Sara has documented these methods here: python version and R version.
-
Xavier M commented on the post, An Autonomous Lighted Insect Trap to Assess Aquatic Ecosystem Health 1 year, 2 months ago
Dear Mike, congratulation for this nice development! I understand from your description that you focus on adults, but I didn’t clearly understand if the device is set underwater or close to stream to focus insects […]
-
Xavier M became a registered member 1 year, 2 months ago
-
Kurt@UR started the topic Inexpensive DO probe recommendations in the forum Environmental Sensors 1 year, 2 months ago
Hi Water Quality fans,
I would like to hear people’s experience with inexpensive dissolved oxygen (DO) probes, especially over long periods of time left in a river and if there are recommendations on what probes to use. The desire is to keep the probe in a river 24/7. The application is in an urban environment somewhat hidden but still near…[Read more]
-
BrianJastram replied to the topic AM2315C Compatibility in the forum Monitor My Watershed 1 year, 2 months ago
I got it to work.
I edited the libraries and logging program to use the new sensor. https://github.com/brianjastram/GHWX/tree/main/GHWX4 -
neilh20 started the topic Not able to download readings in the forum Monitor My Watershed 1 year, 2 months ago
I’m just wondering if anybody is seeing a problem with download readings. I’m not able to download readings – its timing out after 5minutes -sometimes it seems to work but its not clear why.
https://github.com/WikiWatershed/monitor-my-watershed/issues
I realize there are some nifty ways of compressing data – and it may not all be quickly…[Read more]
-
jpeytonj replied to the topic Why is 12V power on Mayfly V1.1 (rev A) nominally only 11.3V? in the forum Mayfly Data Logger 1 year, 2 months ago
Wow! Thank you again.
I am so impressed by your detailed, expert, and helpful response.