Welcome to EnviroDIY, a community for do-it-yourself environmental science and monitoring. EnviroDIY is part of WikiWatershed, a web toolkit designed to help citizens, conservation practitioners, municipal decision-makers, researchers, educators, and students advance knowledge and stewardship of fresh water. New to EnviroDIY? Start here

Gen 2 Hydros 21 CTD and ModularSensors?

Home Forums Environmental Sensors Gen 2 Hydros 21 CTD and ModularSensors?

Viewing 2 reply threads
  • Author
    Posts
    • #15669
      Matt Barney
      Participant

      Has ModularSensors been updated to accommodate the Gen 2 Hydros 21? It was mentioned in this post that an update was necessary.

      I looked in the release notes, but didn’t find any reference to a change having been made for Gen 2.

      Thanks,

      Matt

    • #15672
      Shannon Hicks
      Moderator

      There was a very small adjustment made several months ago to the delay time between commands to make communication with the Meter Group Gen 2 CTD sensor a little more reliable.  I don’t remember the exact date, but the latest release of ModularSensors definitely works with them.

    • #15674
      Matt Barney
      Participant

      Thank you.

Viewing 2 reply threads
  • You must be logged in to reply to this topic.