neilh20 replied to the topic Library alternatives to achieve same goal as dataLogger in Modular Sensors in the forum Mayfly Data Logger 2 weeks, 5 days ago
@cameronlight, I had a suggestion to try replit.com – enabled an account and it allows 10apps to be built free.
I tried “Create a curl script with Oauth2 access to post 3 values to google sheets”
I was logged into my google account, for latter testing. When asked to allow replit permissions pretty have to allow it all it seems, p…[Read more]
-
neilh20 replied to the topic Library alternatives to achieve same goal as dataLogger in Modular Sensors in the forum Mayfly Data Logger 2 weeks, 6 days ago
Oh very interesting needing to be clear about security of readings. Hard to do but a requirement for some property owners.
I was interested in doing something with sheets, however it was to learn about Oauth2 security as I remember. Obviously security access for google is core to the simplicity of their interfaces/APIs – but how does it work.…[Read more]
-
neilh20 replied to the topic Library alternatives to achieve same goal as dataLogger in Modular Sensors in the forum Mayfly Data Logger 2 weeks, 6 days ago
Hi @cameronlight, gosh fascinating to do some lateral thinking.
You would need to publish your whole program – preferably on a traceable git, like github.com.
The challenge in software is abstracting the complicated stuff (service layers) to make it look simple by encapsulating it into a simple interface.
Its always fascinating when someone…[Read more]
-
neilh20 commented on the post, Monitor My Watershed: New Release! 2 months, 2 weeks ago
Thanks for the update and the details. There’s so much work goes into the infrastructure for a remote automated monitoring device—the software releases being part of it. Thanks so much for detailing it. One o […]
-
neilh20 replied to the topic Primary powering in cold settings in the forum Infrastructure and Equipment 2 months, 3 weeks ago
Well as you can see this thread is almost 3 years old. I haven’t tried anything more than what was mentioned above. Your analysis is solid however its dealing with any current pulses and battery voltage measurement circuit.
-
neilh20 replied to the topic POST monitormywatershed.org in the forum Monitor My Watershed 2 months, 3 weeks ago
I’ve had some response from staging.monitormywatershed.org:80
but then it seems to become unreliable.
https://github.com/WikiWatershed/monitor-my-watershed/issues/752
-
neilh20 started the topic POST monitormywatershed.org in the forum Monitor My Watershed 3 months ago
Hello Just wondering what are the target POST
It seems this simple idea can’t be kept working https://github.com/WikiWatershed/monitor-my-watershed/issues/682
and what is the POST for staging for testing.
What’s not working for me is monitormywatershed.org:80 & staging.monitormywatershed.org:80
It used to sometime ago.
-
neilh20 commented on the post, A River Flood Monitoring System for Rapid Deployment 3 months, 1 week ago
Wow looks fascinating. While the SWaP-C mechanical looks so nice, and it’s the open-source software on opensource readable hardware that can make it so nicely extensible. It’s great to see the Stonefly’s SAMD5 […]
-
neilh20 started the topic home-assistant Roll your own logger/sensor in the forum Other Data Loggers 4 months, 3 weeks ago
I’ve been trying home-assistant.io/ HA – a centralized “logger” that manages peripheral sensors or actuators. Might be better for control algorithms. It has some eye dazzling candy, and an ever increasing number of plug-n-play commercial devices.
For any software, and particularly open-source software, I like to start with a target sensor, f…[Read more]
-
neilh20 replied to the topic Issue with USB not connecting in the forum Mayfly Data Logger 7 months ago
Nuts that it sounds like the switch might be oxidizing. The switch solves a power vampire problem by switching off the CP210x – so I would expect the processor to carry on working. You might check what the humidity levels are in the unit, ensure that its largely isolated from fogs and possibly put in some dessicant to dry it out. At one point I…[Read more]
-
neilh20 replied to the topic Logging data from Milone eTape in the forum Environmental Sensors 8 months ago
Hi Eric. this is a voltage sensor, so it fits a pretty basic type of sensor, measure the voltage and then translate it to depth.
For a sensor, layers of calibration give value. Calibration of the sensor to defined units (V to mm), and calibration of the water height to the measured height in the flume.
The accuracy sounds pretty reasonable, for…[Read more]
-
neilh20 replied to the topic Logging data from Milone eTape in the forum Environmental Sensors 8 months, 1 week ago
Good to hear. and definitely very interested in use with a flume. What range of water depth measurement are you looking for and depth accuracy of measurement.
Typically, because ADCs are got good around 0.0V and rail – the Sensor range from 0.0 to full range, the Voltage range is from 10%Rail to 90%Rail (eg 0.3V to 3.0V for 3.3VDC rail) and t…[Read more]
-
neilh20 replied to the topic Logging data from Milone eTape in the forum Environmental Sensors 8 months, 1 week ago
Hi Eric – I’ve purchased and looked at using the eTape.
I was just wondering what made you think they are “calibrated” – that is the “0.0” markings relates to a defined voltage. Usually this is shown for a calibrated sensor. Similarly for a Full Scale relates to a known Voltage.?
looking at the graphs, they describe “0-5VDC Linear Re…[Read more]
-
neilh20 replied to the topic Abnormal power usage? in the forum Mayfly Data Logger 8 months, 1 week ago
Hello Elliot, gosh too bad for the experience. Its a core issue of how to ensure there is enough power, and then also recover from low power events. However to be able to get some help its best to post the details of the two systems. Need to phrase the problem with enough detail that some one else might be able to comment. Battery size and so…[Read more]
-
neilh20 replied to the topic Hydros 21 Depth/Conductivity During low temps in the forum Environmental Sensors 9 months, 3 weeks ago
Hi Jake, no “pressure sensor” is going to be able to be linear/accurate if ice is forming and expanding in the protective enclosure round the pressure sensor. My guess is the whole sensor would have to be specially designed to allow for the ice expansion to even survive a freezing event.
My hypothesis (guess) would be that its the nearly…[Read more]
-
neilh20 replied to the topic Hydros 21 Depth/Conductivity During low temps in the forum Environmental Sensors 9 months, 3 weeks ago
I wonder what the water temperature is, or if there are water temperature changes, when this is happening.
From the graph it reads the water level is at 20″ depth then on the 10th Feb it drops by up to 5″ for some time (hours?) before recovering, with 3 other similar but not us pronounced events
IF any for of ice could build up in a pressure…[Read more]
-
neilh20 started the topic Not able to download readings in the forum Monitor My Watershed 10 months, 1 week ago
I’m just wondering if anybody is seeing a problem with download readings. I’m not able to download readings – its timing out after 5minutes -sometimes it seems to work but its not clear why.
https://github.com/WikiWatershed/monitor-my-watershed/issues
I realize there are some nifty ways of compressing data – and it may not all be quickly…[Read more]
-
neilh20 replied to the topic Artifactual troughs and flickers in recorded stream depth in the forum Monitor My Watershed 1 year ago
@d_manning just wondering if you have had any insights 🙂
-
neilh20 replied to the topic Artifactual troughs and flickers in recorded stream depth in the forum Monitor My Watershed 1 year, 2 months ago
I did some blog posts in 2016 with a number of depth sensors that quoted an error for a very wide temperature compensation. They where the Insitu LT500 (best), Keller Nanolevel, Keller Acculevel, Keller Level gage (worst).
I setup a situation with the depth sensors in a jar of water (low depth) with a good solar aspect to test how well they met…[Read more]
-
neilh20 replied to the topic Artifactual troughs and flickers in recorded stream depth in the forum Monitor My Watershed 1 year, 2 months ago
As you say from 2nd sept – something changed, after that it looks to me like its is triggered by the temperature changes. Its just a visual analysis, but also using the conductivity. With a rain event the conductivity also typically changes, and of course temperature can change.
For daily diurnal cycle after sept 2 the temperature starts varying…[Read more]
- Load More