Jake Lemon replied to the topic Mayfly Dissolved Oxygen Sensor in the forum Mayfly Data Logger 6 years, 2 months ago
Hi All,
Just following up on this. Shannon and I have exchanged emails off of the forum about setting up the Mayfly to work with the Yosemitech Sensor. Shannon, I’m curious as to the status of this?
Thanks,
Jake
-
Jake Lemon replied to the topic Sending Data Through Verizon Network in the forum Mayfly Data Logger 6 years, 2 months ago
Thanks Shannon! I’ll see what I can do.
-
Jake Lemon started the topic Sending Data Through Verizon Network in the forum Mayfly Data Logger 6 years, 2 months ago
Hi All,
I have a station deployed in a location with marginal cell coverage via AT&T. Verizon seems to be have better coverage. Can we update the Mayfly to send data through the Verizon network?
Thanks,
Jake
-
Jake Lemon started the topic Voltage Threshold for Data Upload Through Cell Network in the forum Mayfly Data Logger 6 years, 2 months ago
Hi There,
I have a couple stations that we deployed in forested areas. After a couple weeks the battery voltage settled at around 3.7v, dropping below that at times and rising above at times. When the voltage drops below 3.7v our logger stops sending data through the cell network. Would it be possible to decrease the threshold and see if we can…[Read more]
-
Jake Lemon started the topic Uploading Data to data.envirodiy.org in the forum Miscellaneous 6 years, 3 months ago
I’m trying to upload a csv file downloaded from a Mayfly station to data.envirodiy.org. I’m getting an error message that states “Failure to upload data. This file corresponds to another site”. I’m certain that this file came from the site I’m attempting to upload it to. I suspect there is a formatting issue with my csv. I’ve attached csv here.…[Read more]
-
Jake Lemon started the topic 4G Signal Tester in the forum Mayfly Data Logger 6 years, 5 months ago
Are there plans or instructions available for building/programming a 4G signal tester?
-
Jake Lemon replied to the topic Parameter Threshold Notifications in the forum Mayfly Data Logger 6 years, 7 months ago
Thanks Adam!
-
Jake Lemon started the topic Parameter Threshold Notifications in the forum Mayfly Data Logger 6 years, 7 months ago
Has anyone set up notifications when Mayfly logger stations data exceeds a prescribed threshold? For example, if conductivity were to exceed 500 us/cm an email would be sent to a designated email address.
-
Jake Lemon replied to the topic Continuous Phosphorous Monitoring in the forum Environmental Sensors 6 years, 7 months ago
Thanks Scott!
-
Jake Lemon replied to the topic Mayfly Dissolved Oxygen Sensor in the forum Mayfly Data Logger 6 years, 8 months ago
Thanks for the great info all!
If I were looking to add the Yosemitech standard model to a Mayfly Station with a CTD and Campbell Turbidity sensor would I need to enhance the power capability? Bigger battery…bigger panel? Do you have code for the Yosemitech? Are there other considerations I need to take into account?
Thanks again.
-
Jake Lemon started the topic Continuous Phosphorous Monitoring in the forum Environmental Sensors 6 years, 8 months ago
Any suggestions on continuous total phosphorus sensors?
-
Jake Lemon started the topic Mayfly Dissolved Oxygen Sensor in the forum Mayfly Data Logger 6 years, 9 months ago
I’m working with a watershed groups located in a watershed with intense CAFO activity. They are interested in monitoring DO continuously using the Mayfly EnviroDIY Monitoring Station. I was recommended the Zebra-Tech Optical DO sensor which costs nearly 3500. I’m sure this is a great sensor but is a little expensive for this group. Any…[Read more]
-
Jake Lemon became a registered member 6 years, 9 months ago
Welcome to EnviroDIY, a community for do-it-yourself environmental science and monitoring. EnviroDIY is part of